Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer

INSTALLATION INSTRUCTIONS

Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer

Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & MixerBravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer

Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer

  1. Pull handle outward and turn to blue sides to regulate cold water, In contrast to red to regulate hot water.
  1. (a) Cover the Escutcheon (23) onto the connector of water supplies and against the wall.

(b) Tighten Wall Tube (24) to the connector of water supplies after winding Teflon Tape on it.

Note: Don’t over tighten to avoid damage.

  1. Tighten the Shower Head (25) to the Walk Tube (24).

Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer

  1. Cover the Escutcheon (19) onto the Body Assembly and against the wall.

Note: Make the notes on the Escutcheon downward when installing it.

Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer

  1. Install Handle (11) with Set Screw (12) to the Body Assembly and tighten it, then put the plug (13) into the hole on the handle.

 

Operation:

(a) Open Body Handle that water flow from Hand Shower.

(b) Open Body Handle, Pull Knob outward and rotate clockwise 90° that water flows from Shower Head.

Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & MixerBravat Gold Square Wall Mount Shower Head With Hand-Held Shower & MixerBravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer

  1. Basic-size, according to the embedded box to open the hole on solid wall, should consider installing the metope of the distance between 60-75mm, for example, after blank wall in the shop, the ceramic tile surface to increase the thickness of the 20 mm, so PiQiang in the depth of the hole should be chosen 40 to 55 mm.
  2. Hole bottom should remain flat so that subsequent adjustment embedded box of vertical and horizontal convenient installation for the principle
  3. Pay attention to the direction of the up and down or so embedded box, on the left by hot water pipes, right after the cold water pipes, pick up and down the mixed water pipes.
  4. After the pipe connection, according to the pipeline arrangement, and open the corresponding channel slot tube in the blank wall.
  5. Embedded box fixed before, to embed box and trial test and pipe water clean connection pipe, and test before mixing water channels should be open.
  6. Test before opening the switch valve core, open the water to test around inlet pipe is connected closely with no leakage and the water pipe test after dosing open state, weather to test on the mixed water pipe connection without leakage. At the same time clean tube foreign bodies in case of influencing water control valve function.
  7. It will be embedded in a box into the solid wall with a self-tapping screw that is fixed on the wall.
  8. With parallel ruler for correction of embedded box of horizontal and vertical direction to embed box into a level with the ground, and metope as 90°. In the absence of good correction will influence the control panel installation effect.

Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer

Once again confirm the pipe connection is correct, try no leakage, water shower other embedded with the packing box and pipe joint is fixed

Solid wall embedded box is installed, laid our behind the wall can be a follow-up control valve installation

Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer

The lying of the wall not to embed box is open, lest the box into the packing after solidification effect of control valve installation

Control valve set surface for plating and smooth surface should be kept inside the original packaging before installation to prevent scratches, corrosion, and lost.

Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer

Laid metope ceramic tile or other adornment metope, keep the metope smooth, with embedded box into 90″ vertically

Along with the embedded highlights, the glass on the edge glue, embedded box to improve waterproof performance prolongs service life.

Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer

Cut oof using a cutting tool embedded box of highlightings, keep away from the wall 2-4mm highly advisable.

Try yo remove embedded lifted the lid plate and water components

Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer

Installed control panel, check on panel hole protecting glue before set cut, such as unprotected glue set directly into the panel is easy to scratch panel

Install the switch handle, with packing with small hexagonal wrench clockwise to switch handle is fixed on a main valve spool control valve in, install decorative rubber plugs.

Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer

Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer

 

Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer

Hand-Held Shower

Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer


Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer

Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer

  1. (a) Tighten Connector (26) with Teflon Tape to Water Supplies.

Note: Don’t over tighten to avoid damage.

(b) Place Hand Shower Holder (38) onto Connector and fix it with Set Screws (31).

(c) According to the holes of Hand Shower Holder confirm the location of mounting hole on the wall, Knock into the Anchor (27) and fix the Hand Shower Holder with Screw (37).

Bravat Gold Square Wall Mount Shower Head With Hand-Held Shower & Mixer

  1. Tighten one side of Shower Hose (36) onto Hand Shower (39), and another onto Joint.

Note: Don’t over tighten to avoid damage.

  1. When installation is complete, check all connections for leaks.

 

 